{"id":10761,"date":"2026-11-26T21:02:08","date_gmt":"2026-11-26T21:02:08","guid":{"rendered":"https:\/\/www.frigosys.com\/?p=10761"},"modified":"2026-11-26T21:02:08","modified_gmt":"2026-11-26T21:02:08","slug":"uzum-soguk-hava-deposu","status":"publish","type":"post","link":"https:\/\/www.frigosys.com\/tr\/uzum-soguk-hava-deposu\/","title":{"rendered":"\u00dcz\u00fcm So\u011fuk Hava Deposu: Ka\u00e7 Derece, Hangi Nem, Nas\u0131l Bir Oda?"},"content":{"rendered":"<p>Sofral\u0131k \u00fcz\u00fcm so\u011fuk hava deposunda -1 ile 0 \u00b0C aras\u0131nda ve %90-95 ba\u011f\u0131l nemde saklanmal\u0131d\u0131r; tane eti s\u0131cakl\u0131\u011f\u0131n\u0131n depolama boyunca -0,5 ile 0 \u00b0C aras\u0131nda kalmas\u0131 hedeflenir. Bu de\u011ferlere ula\u015fmak i\u00e7in \u00fcz\u00fcm\u00fcn hasattan sonra h\u0131zla \u00f6n so\u011futmaya al\u0131nmas\u0131, kur\u015funi k\u00fcfe kar\u015f\u0131 SO2 uygulanmas\u0131 ve odadaki hava h\u0131z\u0131n\u0131n kontroll\u00fc tutulmas\u0131 gerekir.<\/p>\n<p>Manisa\u2019da Sultani \u00c7ekirdeksiz paketleyen bir i\u015fletme de, Denizli\u2019den ihracata k\u0131rm\u0131z\u0131 \u00e7e\u015fit haz\u0131rlayan bir ihracat\u00e7\u0131 da ayn\u0131 sorunla kar\u015f\u0131la\u015f\u0131r: \u00fcz\u00fcm hasattan sonra h\u0131zla su kaybeder, sap kurur ve karar\u0131r, taneler d\u00f6k\u00fcl\u00fcr ve k\u00fcf bir taneden di\u011ferine y\u00fcr\u00fcr. Bu rehberde s\u0131cakl\u0131k, nem, \u00f6n so\u011futma, SO2, kontroll\u00fc atmosfer ve oda tasar\u0131m\u0131n\u0131 s\u0131ras\u0131yla ele al\u0131yoruz.<\/p>\n<h2>\u00dcz\u00fcm depo s\u0131cakl\u0131\u011f\u0131 ka\u00e7 derece olmal\u0131?<\/h2>\n<p>Olgun sofral\u0131k \u00fcz\u00fcm i\u00e7in \u00f6nerilen oda s\u0131cakl\u0131\u011f\u0131 -1 ile 0 \u00b0C\u2019dir. \u00dcz\u00fcm so\u011fu\u011fa hassas bir meyve de\u011fildir; yani d\u00fc\u015f\u00fck s\u0131cakl\u0131kta \u00fc\u015f\u00fcme zarar\u0131 g\u00f6rmez. As\u0131l s\u0131n\u0131r donmad\u0131r. Tanelerin donma noktas\u0131 \u015feker oran\u0131na g\u00f6re de\u011fi\u015fir; kaynaklar bu de\u011feri yakla\u015f\u0131k -2 \u00b0C ile -3 \u00b0C aras\u0131nda verir. Sap (salk\u0131m iskeleti) ise tanelerden \u00f6nce donar: sapta donma zarar\u0131n\u0131n -1 \u00b0C civar\u0131nda ba\u015flayabilece\u011fi belirtilir. Bu nedenle oda termostat\u0131n\u0131 -1 \u00b0C\u2019nin alt\u0131na indirmek risklidir, \u00f6zellikle sap donmas\u0131na daha hassas olan, olgunlu\u011fu tam olmayan partilerde ve yeni \u00e7e\u015fitlerde.<\/p>\n<p>S\u0131cakl\u0131\u011f\u0131n sabit tutulmas\u0131 da en az ayar noktas\u0131 kadar \u00f6nemlidir. Kur\u015funi k\u00fcf (Botrytis cinerea) -0,5 \u00b0C gibi d\u00fc\u015f\u00fck s\u0131cakl\u0131klarda bile geli\u015febildi\u011fi i\u00e7in so\u011fuk tek ba\u015f\u0131na yeterli de\u011fildir; dalgalanan bir oda hem k\u00fcf\u00fc hem su kayb\u0131n\u0131 h\u0131zland\u0131r\u0131r. Farkl\u0131 \u00fcr\u00fcnlerin s\u0131cakl\u0131klar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131rmak isterseniz <a href=\"https:\/\/www.frigosys.com\/tr\/gidalarin-soguk-oda-depolama-sicakliklari\/\">g\u0131dalar\u0131n so\u011fuk oda depolama s\u0131cakl\u0131klar\u0131<\/a> tablomuza bakabilirsiniz.<\/p>\n<h2>Nem ve hava h\u0131z\u0131: sap\u0131 ye\u015fil tutman\u0131n yolu<\/h2>\n<p>\u00dcz\u00fcm salk\u0131m\u0131nda sap\u0131n solunumu tanelerinkinden yakla\u015f\u0131k 15 kat y\u00fcksektir; su kayb\u0131 ve kararma \u00f6nce sapta g\u00f6r\u00fcl\u00fcr. Bu y\u00fczden oda nemi %90-95 aral\u0131\u011f\u0131nda tutulmal\u0131d\u0131r. Nemin d\u00fc\u015fmesi sap\u0131 kurutur, tane d\u00f6k\u00fclmesini art\u0131r\u0131r ve \u00fcr\u00fcn\u00fcn g\u00f6r\u00fcnt\u00fcs\u00fcn\u00fc bozar.<\/p>\n<p>Hava h\u0131z\u0131 konusunda kaynaklar biraz farkl\u0131 rakamlar verir. Kaliforniya \u00dcniversitesi rehberi depolama s\u0131ras\u0131nda yakla\u015f\u0131k 0,10-0,20 m\/s (20-40 ft\/dk) \u00f6l\u00e7\u00fcl\u00fc bir hava hareketi \u00f6nerirken, uluslararas\u0131 bir depolama k\u0131lavuzu palet s\u0131ralar\u0131 aras\u0131nda 0,25-0,38 m\/s (15-23 m\/dk) de\u011ferini verir. Pratik sonu\u00e7 \u015fudur: hava t\u00fcm paletlere e\u015fit ula\u015fmal\u0131 ama \u00fcr\u00fcn\u00fcn \u00fczerinden gere\u011finden h\u0131zl\u0131 ge\u00e7erek onu kurutmamal\u0131d\u0131r. Evaporat\u00f6r se\u00e7imi ve hava da\u011f\u0131t\u0131m\u0131 bu dengeye g\u00f6re yap\u0131lmal\u0131d\u0131r. Konuyu ayr\u0131nt\u0131l\u0131 olarak <a href=\"https:\/\/www.frigosys.com\/tr\/soguk-depoda-nem-kontrolu\/\">so\u011fuk depoda nem kontrol\u00fc<\/a> yaz\u0131m\u0131zda anlatt\u0131k.<\/p>\n<h2>\u00d6n so\u011futma: hasattan sonraki ilk saatler<\/h2>\n<p>\u00dcz\u00fcm depoya s\u0131cak girerse kay\u0131p depoda de\u011fil, ilk saatlerde ba\u015flar. Solunum h\u0131z\u0131 0 \u00b0C\u2019de 1-2 ml CO2\/kg\u00b7saat iken 20 \u00b0C\u2019de 12-15 ml CO2\/kg\u00b7saat\u2019e \u00e7\u0131kar; yani tarladan gelen s\u0131cak \u00fcz\u00fcm, so\u011futulmu\u015f \u00fcz\u00fcme g\u00f6re yakla\u015f\u0131k on kat h\u0131zl\u0131 \u201cya\u015flan\u0131r\u201d. Bu nedenle so\u011futma m\u00fcmk\u00fcn olan en k\u0131sa s\u00fcrede ba\u015flamal\u0131, SO2 uygulamas\u0131 da hasattan sonraki 12 saat i\u00e7inde yap\u0131lmal\u0131d\u0131r.<\/p>\n<p>Kaliforniya\u2019daki bir\u00e7ok \u00fcz\u00fcm \u00f6n so\u011futma tesisi, \u00fcr\u00fcn ile hedef s\u0131cakl\u0131k aras\u0131ndaki fark\u0131n 7\/8\u2019ini 6 saat veya daha k\u0131sa s\u00fcrede kapatacak \u015fekilde tasarlan\u0131r. Bunun en yayg\u0131n yolu zorlanm\u0131\u015f hava ile so\u011futmad\u0131r: paletler iki s\u0131ra h\u00e2linde dizilir, \u00fcstleri ve yanlar\u0131 \u00f6rt\u00fcl\u00fcr, fan so\u011fuk havay\u0131 kutular\u0131n i\u00e7inden ge\u00e7meye zorlar. \u00d6n so\u011futma ayr\u0131 bir odada, y\u00fcksek so\u011futma kapasitesi, y\u00fcksek hava h\u0131z\u0131 ve y\u00fcksek nemle yap\u0131l\u0131r; so\u011fuyan paletler ard\u0131ndan depolama odas\u0131na al\u0131n\u0131r. Fan duvar\u0131, branda ve hava plenumuyla \u00e7al\u0131\u015fan zorlanm\u0131\u015f hava \u00f6n so\u011futma odalar\u0131n\u0131 kendimiz projelendirip kuruyoruz. Y\u00f6ntemin ayr\u0131nt\u0131lar\u0131 i\u00e7in <a href=\"https:\/\/www.frigosys.com\/tr\/zorlanmis-hava-ile-sogutma\/\">zorlanm\u0131\u015f hava ile so\u011futma<\/a> sayfam\u0131z\u0131 okuyabilirsiniz.<\/p>\n<h2>SO2 uygulamas\u0131n\u0131n temelleri<\/h2>\n<p>Kur\u015funi k\u00fcf, sofral\u0131k \u00fcz\u00fcm\u00fcn en y\u0131k\u0131c\u0131 depo hastal\u0131\u011f\u0131d\u0131r ve yaln\u0131zca h\u0131zl\u0131 so\u011futmayla \u00f6nlenemez. Bu y\u00fczden d\u00fcnyada yayg\u0131n uygulama iki a\u015famal\u0131d\u0131r:<\/p>\n<ul>\n<li><b>Depoda f\u00fcmigasyon:<\/b> Paketlemeden hemen sonra ilk SO2 uygulamas\u0131 yap\u0131l\u0131r, depolama boyunca 7-10 g\u00fcnde bir daha d\u00fc\u015f\u00fck dozlu tekrarlar uygulan\u0131r. Ara\u015ft\u0131rmalar, 0 \u00b0C\u2019de k\u00fcf sporlar\u0131n\u0131 \u00f6ld\u00fcrmek i\u00e7in konsantrasyon ile s\u00fcrenin \u00e7arp\u0131m\u0131n\u0131n en az 100 ppm\u00b7saat olmas\u0131 gerekti\u011fini g\u00f6stermi\u015ftir. \u0130lk f\u00fcmigasyonun zorlanm\u0131\u015f hava ile so\u011futma s\u0131ras\u0131nda yap\u0131lmas\u0131, gaz\u0131n paletin ortas\u0131ndaki kutulara kadar ula\u015fmas\u0131n\u0131 sa\u011flar.<\/li>\n<li><b>Kutu i\u00e7i SO2 pedleri:<\/b> F\u00fcmigasyon yap\u0131lamayan uzun deniz ta\u015f\u0131mac\u0131l\u0131\u011f\u0131nda (10 g\u00fcnden uzun) veya uzun perakende s\u00fcrelerinde, SO2\u2019yi yava\u015f salan pedler delikli polietilen i\u00e7 po\u015fetle birlikte kullan\u0131l\u0131r.<\/li>\n<\/ul>\n<p>Dozu a\u015fmak da zararl\u0131d\u0131r: olgunla\u015fmam\u0131\u015f, s\u0131cak veya \u00e7atlak taneler SO2 ile kolay a\u011far\u0131r ve bu zarar depolama uzad\u0131k\u00e7a belirginle\u015fir. T\u00fcrkiye\u2019de Sultani \u00c7ekirdeksiz \u00fczerinde yap\u0131lan bir \u00e7al\u0131\u015fmada, tek SO2 jenerat\u00f6rl\u00fc modifiye atmosferli po\u015fet (MAP) uygulamas\u0131nda kal\u0131nt\u0131n\u0131n depolaman\u0131n ikinci ay\u0131ndan sonra 10 ppm s\u0131n\u0131r\u0131n\u0131 a\u015ft\u0131\u011f\u0131 bildirilmi\u015ftir. Hedef pazar\u0131n kal\u0131nt\u0131 kurallar\u0131 mutlaka \u00f6nceden kontrol edilmeli, gaz uygulamalar\u0131 e\u011fitimli ekiplerce yap\u0131lmal\u0131d\u0131r.<\/p>\n<h2>\u00dcz\u00fcm i\u00e7in atmosfer kontroll\u00fc depo gerekli mi?<\/h2>\n<p>K\u0131sa cevap: elma ve armutta oldu\u011fu kadar net bir fayda yoktur. ABD\u2019deki hasat sonras\u0131 rehberleri, %2-5 O2 ve %1-5 CO2 i\u00e7eren kontroll\u00fc atmosferin (KA) sofral\u0131k \u00fcz\u00fcm i\u00e7in \u015fu an \u00f6nerilmedi\u011fini, \u00e7\u00fcnk\u00fc faydas\u0131n\u0131n s\u0131n\u0131rl\u0131 oldu\u011funu ve k\u00fcf kontrol\u00fcn\u00fcn zaten SO2 ile yap\u0131ld\u0131\u011f\u0131n\u0131 belirtir. \u00d6te yandan y\u00fcksek CO2\u2019nin i\u015fe yarad\u0131\u011f\u0131n\u0131 g\u00f6steren sonu\u00e7lar da vard\u0131r: havaya %10-15 CO2 eklenmesi \u00e7e\u015fide g\u00f6re 2-4 hafta k\u00fcf\u00fc bask\u0131layabilir, %5-10 CO2\u2019nin KA ile birlikte SO2\u2019ye yak\u0131n etki verdi\u011fi de bildirilmi\u015ftir.<\/p>\n<p>Sonu\u00e7lar \u00e7e\u015fide ve hasat zaman\u0131na g\u00f6re de\u011fi\u015fir. Thompson Seedless \u00fczerinde yap\u0131lan bir denemede, k\u00fcf\u00fc kontrol etmek i\u00e7in en az %15 CO2 gerekmi\u015f; ge\u00e7 hasat edilmi\u015f \u00fcz\u00fcmde %15 CO2 + %3-12 O2 ile 12 haftaya kadar depolama \u00f6nerilmi\u015f, ancak erken hasat edilen \u00fcz\u00fcmde %10\u2019un \u00fczerindeki CO2 sap ve tanede kahverengile\u015fmeye yol a\u00e7m\u0131\u015f ve KA \u00f6nerilmemi\u015ftir. T\u00fcrkiye\u2019de Sultani \u00c7ekirdeksiz ile yap\u0131lan bir \u00e7al\u0131\u015fmada ise atmosfer kontroll\u00fc mod\u00fcl SO2 jenerat\u00f6rleriyle birlikte kullan\u0131ld\u0131\u011f\u0131nda \u00fcz\u00fcm\u00fcn 150 g\u00fcn depolanabilece\u011fi sonucuna var\u0131lm\u0131\u015ft\u0131r. Yani KA, \u00fcz\u00fcmde SO2\u2019nin yerine ge\u00e7en haz\u0131r bir re\u00e7ete de\u011fil; \u00e7e\u015fide, olgunlu\u011fa ve hedef pazara g\u00f6re denenmesi gereken bir se\u00e7enektir. Yat\u0131r\u0131m d\u00fc\u015f\u00fcn\u00fcyorsan\u0131z <a href=\"https:\/\/www.frigosys.com\/tr\/hizmetlerimiz\/atmosfer-kontrollu-depolar\/\">atmosfer kontroll\u00fc depolar<\/a> sayfam\u0131zda sistemin nas\u0131l \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 g\u00f6rebilirsiniz.<\/p>\n<h2>\u00c7e\u015fide g\u00f6re depolama s\u00fcresi<\/h2>\n<p>\u00dcz\u00fcm\u00fcn depoda ne kadar dayanaca\u011f\u0131 \u00e7e\u015fide, hasat olgunlu\u011funa, hasattan \u00f6nce ya\u011fmur al\u0131p almad\u0131\u011f\u0131na ve s\u0131cakl\u0131k y\u00f6netimine ba\u011fl\u0131d\u0131r. Kaynaklardaki aral\u0131klar a\u015fa\u011f\u0131dad\u0131r:<\/p>\n<table>\n<tr>\n<th>\u00c7e\u015fit \/ grup<\/th>\n<th>Ko\u015ful<\/th>\n<th>Kaynaklardaki s\u00fcre<\/th>\n<\/tr>\n<tr>\n<td>Avrupa tipi (Vitis vinifera) sofral\u0131k \u00fcz\u00fcmler, genel<\/td>\n<td>-1 ile 0 \u00b0C, %90-95 nem<\/td>\n<td>2-6 ay<\/td>\n<\/tr>\n<tr>\n<td>Red Globe, Crimson Seedless, Emperor, Ribier<\/td>\n<td>Ayn\u0131 ko\u015fullar, SO2 ile<\/td>\n<td>Grubun en uzun depolanan \u00e7e\u015fitleri olarak ge\u00e7er<\/td>\n<\/tr>\n<tr>\n<td>Thompson Seedless (Sultani), Flame Seedless<\/td>\n<td>Ayn\u0131 ko\u015fullar, SO2 ile<\/td>\n<td>Kaliforniya\u2019da hasattan sonra 8-10 haftaya kadar pazarlan\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Sultani \u00c7ekirdeksiz (T\u00fcrkiye \u00e7al\u0131\u015fmas\u0131)<\/td>\n<td>0 \u00b0C, %90\u00b15 nem, atmosfer kontroll\u00fc mod\u00fcl + SO2<\/td>\n<td>150 g\u00fcn<\/td>\n<\/tr>\n<tr>\n<td>Amerikan tipi \u00fcz\u00fcmler (Concord vb.)<\/td>\n<td>-0,5 ile 0 \u00b0C, %85-90 nem<\/td>\n<td>Uzun depolamaya uygun de\u011fil: en iyi ko\u015fulda bile 3-4 haftadan fazla iyi dayanmaz (kaynak tablosunda 1-2 ay); SO2\u2019ye hassas oldu\u011fu i\u00e7in SO2 f\u00fcmigasyonu uygulanmaz<\/td>\n<\/tr>\n<\/table>\n<h2>\u00dcz\u00fcm deposu tasar\u0131m\u0131nda dikkat edilecekler<\/h2>\n<h3>\u00d6n so\u011futma ve depolama ayr\u0131 olmal\u0131<\/h3>\n<p>\u00d6n so\u011futma \u00e7ok y\u00fcksek kapasite ister; depolama odas\u0131 ise sabit s\u0131cakl\u0131k ve d\u00fc\u015f\u00fck hava h\u0131z\u0131 ister. \u0130kisini ayn\u0131 odada yapmak hem s\u0131cak \u00fcr\u00fcn\u00fc yava\u015f so\u011futur hem de i\u00e7erideki so\u011fuk \u00fcr\u00fcn\u00fc kurutur. Kapasite hesab\u0131nda \u00fcr\u00fcn\u00fcn giri\u015f s\u0131cakl\u0131\u011f\u0131, g\u00fcnl\u00fck giri\u015f miktar\u0131 ve solunum \u0131s\u0131s\u0131 birlikte de\u011ferlendirilmelidir; <a href=\"https:\/\/www.frigosys.com\/tr\/soguk-oda-sogutma-yuku-hesaplama\/\">so\u011fuk oda so\u011futma y\u00fck\u00fc hesaplama<\/a> sayfam\u0131z ba\u015flang\u0131\u00e7 i\u00e7in yol g\u00f6sterir.<\/p>\n<h3>Yal\u0131t\u0131m ve panel<\/h3>\n<p>Oda -1 \u00b0C\u2019de \u00e7al\u0131\u015ft\u0131\u011f\u0131 i\u00e7in duvar, tavan ve zemin yal\u0131t\u0131m\u0131 yaz s\u0131cakl\u0131\u011f\u0131na g\u00f6re se\u00e7ilmelidir. 0 \u00b0C civar\u0131nda \u00e7al\u0131\u015fan odalarda, yani -1\/0 \u00b0C\u2019lik \u00fcz\u00fcm odalar\u0131nda, 80-100 mm panel kullan\u0131yoruz; -18\/-25 \u00b0C\u2019lik donuk depolarda bu kal\u0131nl\u0131k 120-150 mm\u2019dir. Kesin de\u011fer, b\u00f6lgenin d\u0131\u015f s\u0131cakl\u0131\u011f\u0131na ve \u0131s\u0131 y\u00fck\u00fc hesab\u0131na g\u00f6re belirlenir. Ayn\u0131 tesiste donuk depo da varsa zemin donmas\u0131n\u0131 \u00f6nlemek i\u00e7in zemin \u0131s\u0131tmas\u0131 gerekir; bunu elektrikli \u0131s\u0131t\u0131c\u0131 kabloyla yap\u0131yoruz (<a href=\"https:\/\/www.frigosys.com\/tr\/urunler\/soguk-hava-deposu-icin-yerden-isitma\/\">so\u011fuk hava deposu i\u00e7in yerden \u0131s\u0131tma<\/a>). S\u0131zd\u0131rmaz birle\u015fimler hem enerji kayb\u0131n\u0131 hem de nem dengesini do\u011frudan etkiler. Se\u00e7enekler i\u00e7in <a href=\"https:\/\/www.frigosys.com\/tr\/urunler\/soguk-oda-panelleri\/\">so\u011fuk oda panelleri<\/a> sayfam\u0131za bakabilirsiniz.<\/p>\n<h3>Nem, hava ve kap\u0131lar<\/h3>\n<p>Evaporat\u00f6r ile oda aras\u0131ndaki s\u0131cakl\u0131k fark\u0131n\u0131 k\u00fc\u00e7\u00fck tutan bir tasar\u0131m, odadan \u00e7ekilen nemi azalt\u0131r. Palet s\u0131ralar\u0131 aras\u0131nda hava koridorlar\u0131 b\u0131rak\u0131lmal\u0131, forklift trafi\u011finin yo\u011fun oldu\u011fu giri\u015flerde h\u0131zl\u0131 veya s\u00fcrg\u00fcl\u00fc kap\u0131larla s\u0131cak hava giri\u015fi s\u0131n\u0131rland\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n<h2>\u00dcz\u00fcm deposunu nas\u0131l kuruyoruz?<\/h2>\n<p>\u0130stanbul merkezli bir firma olarak PU\/PIR sandvi\u00e7 panelleri, so\u011fuk oda kap\u0131lar\u0131n\u0131 ve so\u011futma sistemlerini kendi fabrikam\u0131zda \u00fcretiyoruz. Bir \u00fcz\u00fcm deposu projesinde \u015fu ad\u0131mlar\u0131 izliyoruz:<\/p>\n<ul>\n<li>G\u00fcnl\u00fck \u00fcr\u00fcn giri\u015fi, \u00e7e\u015fit, depolama s\u00fcresi ve hedef pazar bilgisiyle \u0131s\u0131 y\u00fck\u00fc hesab\u0131 ve oda yerle\u015fimi haz\u0131rlan\u0131r.<\/li>\n<li>Zorlanm\u0131\u015f hava ile \u00f6n so\u011futma odalar\u0131n\u0131 (fan duvar\u0131, branda, hava plenumu) ve depolama odalar\u0131n\u0131 kendimiz projelendirip kuruyoruz; atmosfer kontroll\u00fc depo isteyen m\u00fc\u015fteriler i\u00e7in KA odalar\u0131 da ayn\u0131 projede planlanabilir.<\/li>\n<li>Kilitli veya kilitsiz paneller, zemin panelleri, mente\u015feli, s\u00fcrg\u00fcl\u00fc ve h\u0131zl\u0131 PVC kap\u0131lar ile monoblok, split, a\u00e7\u0131k tip kondenser \u00fcniteleri veya merkezi sistemlerden projeye uygun olan\u0131 se\u00e7ilir. Standart so\u011futucu ak\u0131\u015fkanlar\u0131m\u0131z R404A, R449A\/R448A ve R134a\/R513A\u2019d\u0131r.<\/li>\n<li><a href=\"https:\/\/www.frigosys.com\/tr\/sogutma-uzaktan-izleme-sistemi\/\">Uzaktan izleme sistemimiz<\/a> alarm bildirimleri g\u00f6nderir; oda s\u0131cakl\u0131\u011f\u0131 uzaktan takip edilebilir.<\/li>\n<li>\u00dcretim, projeye g\u00f6re 3-7 hafta s\u00fcrer. Yurt d\u0131\u015f\u0131nda montaj\u0131 kendi ekibimiz yapar veya bir s\u00fcperviz\u00f6r g\u00f6nderilir. Teslim, \u00fclkeye g\u00f6re EXW veya CIF yap\u0131l\u0131r; \u00f6deme L\/C veya T\/T ile, ko\u015fullar\u0131 her sipari\u015fte belirlenerek yap\u0131l\u0131r. T\u00fcm \u00fcr\u00fcnlerimiz CE i\u015faretlidir, garanti 1 y\u0131ld\u0131r ve yedek par\u00e7alar 3-5 g\u00fcnde g\u00f6nderilir.<\/li>\n<\/ul>\n<p>15 y\u0131l\u0131 a\u015fk\u0131n tecr\u00fcbemizle 40\u2019tan fazla \u00fclkeye \u00fcr\u00fcn g\u00f6nderiyoruz; bug\u00fcne kadar 100\u2019den fazla anahtar teslim proje tamamlad\u0131k ve 500\u2019den fazla firmaya \u00fcr\u00fcn sa\u011flad\u0131k. Meyve depolar\u0131na genel bak\u0131\u015f i\u00e7in <a href=\"https:\/\/www.frigosys.com\/tr\/hizmetlerimiz\/meyve-sebze-depolari\/\">meyve-sebze depolar\u0131<\/a> sayfam\u0131z\u0131 inceleyebilirsiniz.<\/p>\n<h2>S\u0131k\u00e7a sorulan sorular<\/h2>\n<h3>\u00dcz\u00fcm so\u011fuk hava deposunda ka\u00e7 derecede saklanmal\u0131?<\/h3>\n<p>Oda s\u0131cakl\u0131\u011f\u0131 -1 ile 0 \u00b0C, tane eti s\u0131cakl\u0131\u011f\u0131 -0,5 ile 0 \u00b0C aral\u0131\u011f\u0131nda tutulmal\u0131d\u0131r. Sap tanelerden \u00f6nce dondu\u011fu i\u00e7in oda -1 \u00b0C\u2019nin alt\u0131na indirilmemelidir. Nem ise %90-95 olmal\u0131d\u0131r.<\/p>\n<h3>\u00dcz\u00fcm so\u011fuk hava deposunda ka\u00e7 ay dayan\u0131r?<\/h3>\n<p>Avrupa tipi sofral\u0131k \u00fcz\u00fcmler i\u00e7in kaynaklar 2-6 ay aras\u0131 bir s\u00fcre verir. Thompson Seedless gibi \u00e7e\u015fitler genellikle daha k\u0131sa, Red Globe ve Crimson Seedless gibi \u00e7e\u015fitler daha uzun depolan\u0131r. S\u00fcre; olgunluk, hasat \u00f6ncesi ya\u011fmur ve s\u0131cakl\u0131k y\u00f6netimine g\u00f6re de\u011fi\u015fir.<\/p>\n<h3>\u00dcz\u00fcm i\u00e7in atmosfer kontroll\u00fc depo \u015fart m\u0131?<\/h3>\n<p>\u015eart de\u011fildir. Standart uygulama so\u011fuk depo ve SO2\u2019dir. Y\u00fcksek CO2 i\u00e7eren atmosferlerle iyi sonu\u00e7lar al\u0131nan \u00e7al\u0131\u015fmalar olsa da sonu\u00e7lar \u00e7e\u015fide ve hasat zaman\u0131na g\u00f6re de\u011fi\u015fir; erken hasat edilen \u00fcz\u00fcmde y\u00fcksek CO2 zarar verebilir. Uzun s\u00fcreli depolama ve SO2 kal\u0131nt\u0131s\u0131n\u0131 d\u00fc\u015f\u00fcrmek isteyen i\u015fletmeler i\u00e7in de\u011ferlendirilebilir.<\/p>\n<h3>SO2 pedi mi, depoda f\u00fcmigasyon mu?<\/h3>\n<p>\u0130kisi farkl\u0131 ama\u00e7lara hizmet eder. Depoda bekleyen \u00fcz\u00fcmde d\u00fczenli f\u00fcmigasyon yap\u0131l\u0131r; f\u00fcmigasyonun m\u00fcmk\u00fcn olmad\u0131\u011f\u0131 uzun deniz yolculuklar\u0131nda ve perakende s\u00fcrecinde ise kutu i\u00e7i pedler delikli po\u015fetle birlikte kullan\u0131l\u0131r. Her iki y\u00f6ntemde de doz ve kal\u0131nt\u0131 s\u0131n\u0131rlar\u0131na dikkat edilmelidir.<\/p>\n<h3>\u00dcz\u00fcm \u00f6n so\u011futmas\u0131 ne kadar s\u00fcrmeli?<\/h3>\n<p>So\u011futma hasattan hemen sonra ba\u015flamal\u0131d\u0131r. Kaliforniya\u2019daki bir\u00e7ok zorlanm\u0131\u015f hava tesisi, s\u0131cakl\u0131k fark\u0131n\u0131n 7\/8\u2019ini 6 saat veya daha k\u0131sa s\u00fcrede kapatacak \u015fekilde tasarlan\u0131r. SO2 uygulamas\u0131 da hasattan sonraki 12 saat i\u00e7inde yap\u0131lmal\u0131d\u0131r.<\/p>\n<p>\u00dcz\u00fcm deponuzun kapasitesini, oda say\u0131s\u0131n\u0131 ve \u00f6n so\u011futma ihtiyac\u0131n\u0131 birlikte hesaplamak i\u00e7in bize <a href=\"https:\/\/www.frigosys.com\/tr\/iletisim\/\">ileti\u015fim sayfam\u0131zdan<\/a> yazabilirsiniz; 24 saat i\u00e7inde d\u00f6n\u00fc\u015f yap\u0131yor ve teklifimizi iletiyoruz.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sofral\u0131k \u00fcz\u00fcm so\u011fuk hava deposunda -1 ile 0 \u00b0C aras\u0131nda ve %90-95 ba\u011f\u0131l nemde saklanmal\u0131d\u0131r; tane eti s\u0131cakl\u0131\u011f\u0131n\u0131n depolama boyunca -0,5 ile 0 \u00b0C aras\u0131nda kalmas\u0131 hedeflenir. Bu de\u011ferlere ula\u015fmak i\u00e7in \u00fcz\u00fcm\u00fcn hasattan sonra h\u0131zla \u00f6n so\u011futmaya al\u0131nmas\u0131, kur\u015funi k\u00fcfe kar\u015f\u0131 SO2 uygulanmas\u0131 ve odadaki hava h\u0131z\u0131n\u0131n kontroll\u00fc tutulmas\u0131 gerekir. Manisa\u2019da Sultani \u00c7ekirdeksiz paketleyen bir [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2688,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-10761","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized-tr"],"_links":{"self":[{"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/posts\/10761","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/comments?post=10761"}],"version-history":[{"count":2,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/posts\/10761\/revisions"}],"predecessor-version":[{"id":10763,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/posts\/10761\/revisions\/10763"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/media\/2688"}],"wp:attachment":[{"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/media?parent=10761"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/categories?post=10761"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.frigosys.com\/tr\/wp-json\/wp\/v2\/tags?post=10761"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}