Hinged Cold Room Door

Hinged Cold Room Doors for Chiller and Freezer Rooms

Frigo System hinged doors combine high-insulation polyurethane foam with a PVC frame. They are a compact solution for cold rooms in supermarkets, restaurants, hotels, food plants and warehouses.

Technical Specifications

FeatureChiller typeFreezer type
Use0 °C and aboveBelow 0 °C
Leaf68-92 mm, depending on door type68-92 mm, depending on door type
SurfacePolyester-coated steel RAL 9002 or stainless steelPolyester-coated steel RAL 9002 or stainless steel
FramePVC frame covering the panel edgePVC frame
ThresholdNot requiredSunk below floor level
HeatingNot requiredBuilt-in heating

Standard Sizes

Clear openingWall openingTypical use
80×180 cm87×184 cmSmall walk-in coolers
80×190 cm87×194 cmKitchens, restaurants
90×190 cm97×194 cmSupermarkets, hotels
90×200 cm97×204 cmFood plants, personnel access
100×200 cm107×204 cmHand trolleys
120×200 cm127×204 cmRoll containers, wide access

Custom sizes are available on request. Doors include adjustable hinges, an external handle with lock and an internal release handle. The frame and leaf are delivered assembled.

Options: Stainless steel leaf, stainless steel accessories, left or right opening, and other RAL colours besides RAL 9002.

Frequently Asked Questions

How do I calculate the wall opening?
Add 70 mm to the clear width and 40 mm to the clear height.

How is freezing prevented on freezer doors?
The sunk threshold and built-in heating protect the door against icing.

Does the door need maintenance?
Lubricate the hinges every 4 to 6 months.

Get a Quote for This Product