Need a walk-in cooler, freezer, or multi-room cold storage facility without paying distributor markups? A cold room kit from Frigo System gives you everything you need in one shipment: insulated panels, doors, refrigeration unit, controller, and installation hardware. Everything is engineered for your room size and temperature.
We manufacture every kit in our factory and ship it flat-packed to your site. Your installer assembles it with the drawings and cam-lock system we supply.
Get a free quote for your cold room kit →

Proven in the USA: Our Houston, Texas Project
Frigo System delivered a turnkey cold storage project in Houston, Texas, from technical design through procurement and on-site execution.
| Project figure | Houston, Texas |
| Enclosed area | 5,100 m² (about 54,900 sq ft) |
| Cooling units | 29 |
| Insulated sandwich panels | 11,000 m² (about 118,400 sq ft) |
| Doors | 3 automatic sliding cold room doors and 2 insulated high-speed doors |
See the Houston cold storage project.
Local representatives in the USA: Frigo System has representatives in Texas, Detroit and New York. See our representatives on the map.
What’s Included in a Frigo System Cold Room Kit
Each kit is a complete, ready-to-assemble package. Nothing critical is left for you to source locally.
| Component | What you get |
| Insulated panels | PIR sandwich panels (wall, ceiling and floor where required), cut to your dimensions, with cam-lock or tongue-and-groove joints |
| Door | Hinged or sliding cold room door with heated frame (freezers), gasket, handle with inside safety release |
| Refrigeration unit | Condensing unit or monoblock, sized from a full heat load calculation. Condensing units use Bitzer, Dorin, Frascold, Copeland or BOCK compressors |
| Evaporator | Air cooler with electric or hot gas defrost (freezers) |
| Controller | Dixell or Eliwell digital controller with temperature display, alarms and data logging option |
| Accessories | Corner and floor profiles, sealant, pressure relief valve (freezers), LED lighting, strip curtain |
| Documents | Assembly drawings, electrical diagram, installation guide |

Temperature Ranges and Applications
One panel system covers every application. We change the panel thickness, the refrigeration unit and the door to match your temperature.
| Room type | Temperature | Typical products | Typical panel thickness |
| Cooler (chiller) room | +0°C to +10°C (32–50°F) | Fruit, vegetables, dairy, beverages, flowers | 80–100 mm |
| Freezer room | -18°C to -25°C (0 to -13°F) | Frozen meat, poultry, seafood, ice cream | 120–150 mm |
| Blast freezer room | -30°C to -40°C (-22 to -40°F) | Fast freezing of meat, fish, bakery, ready meals | 150–200 mm |
| Pharma / controlled room | +2°C to +8°C or +15°C to +25°C | Vaccines, medicines, lab materials | 80–100 mm |
| Multi-temperature facility | Mixed | Distribution centers, 3PL, processing plants | Per room |
Note: final panel thickness is confirmed by heat load calculation and local climate.
Cold Room Panels for U.S. Projects: Inches and R-Values
Many U.S. buyers compare panels by R-value. This table converts our cam-lock panel data, and panels can also be ordered without a full kit.
| Thickness | U-value | Approx. R-value | Typical use |
| 80 mm (about 3 in) | 0.28 W/m²K | R-20 | Chill rooms, 0 to +5 °C (32–41 °F) |
| 100 mm (about 4 in) | 0.22 W/m²K | R-26 | Low chill and light freeze, -5 to -10 °C (23–14 °F) |
| 120 mm (about 4.7 in) | 0.19 W/m²K | R-30 | Freezer rooms, to -15 °C (5 °F) |
| 150 mm (about 6 in) | 0.14 W/m²K | R-41 | Deep freeze, -18 to -35 °C (0 to -31 °F) |
| 200 mm (about 8 in) | 0.11 W/m²K | R-52 | Blast freezers, -40 °C (-40 °F) and below |
R-values are converted from the U-values (R ≈ 5.68 ÷ U). Recommended use is for an outside temperature of +35 °C (95 °F) and a heat gain limit of 10 W/m². Camlock panels come in 1110 mm or 1135 mm widths (about 44 in) and can run longer than 9 m (about 30 ft). See all our cold room panels.

Popular Cold Room Kit Sizes
We build kits to any dimension in 10 cm (≈4 in) steps. These are the sizes U.S. buyers ask for most often:
| Kit size (ft) | Approx. size (m) | Best for |
| 8 × 10 ft | 2.4 × 3.0 m | Restaurants, cafés, small grocery |
| 10 × 12 ft | 3.0 × 3.7 m | Supermarkets, catering, butcher shops |
| 10 × 20 ft | 3.0 × 6.1 m | Food distributors, farms, florists |
| 20 × 30 ft | 6.1 × 9.1 m | Wholesale, meat and seafood processors |
| 40 × 60 ft and larger | 12 × 18 m + | Pallet storage, cold storage warehouses, 3PL |
Standard internal height is 8–10 ft for walk-ins. For pallet racking we build up to 40 ft (12 m) and more.
Why Buy a Cold Room Kit Factory-Direct?
- Lower cost per square foot.
You buy from the manufacturer, with no distributor or dealer margin in between. For mid-size and large rooms, the savings usually more than cover sea freight.
- One supplier, one responsibility.
Panels, door, refrigeration and controls are designed together. You don’t have to match a panel supplier’s room to another company’s condensing unit.
- Engineered, not guessed.
Every kit starts with a heat load calculation based on your product, daily loading, door openings and local climate. The refrigeration unit is sized to the room, so it isn’t oversized “just in case.”
- Energy-efficient insulation.
High-density PIR panels keep heat out and cut compressor running time. That lowers your electricity bill for the life of the room.
- Fast, clean installation.
Panels arrive cut to size, numbered and ready to lock together. A small crew can typically assemble a walk-in in 1–2 days. Larger facilities take a few weeks, not months.
- Expandable and relocatable.
Modular panels can be taken apart, extended or moved to a new site. That’s ideal for growing businesses and leased buildings.
How Ordering Works
Step 1 – Send your requirements.
Tell us the inside dimensions, the target temperature, the products you’ll store, and your site location. A simple sketch or floor plan is enough.
Step 2 – Receive a technical proposal.
Our engineers calculate the heat load and send a quotation with the panel specification, refrigeration equipment, drawings and delivery terms.
Step 3 – Production.
After you approve, panels and equipment are manufactured and tested in our factory.
Step 4 – Shipping.
Your kit is packed on pallets and loaded into a container. We can combine several rooms in one container and provide the loading documents for customs clearance.
Step 5 – Installation and start-up.
Your local installer assembles the room using our drawings. Our technical team supports the installation and commissioning remotely, or on site for larger projects.
Request your cold room kit quote →
Terms for U.S. Buyers
| Term | Frigo System |
| Production | 3–7 weeks on average, depending on the project and order status; sea freight comes on top |
| Warranty | 1 year under standard terms, can be extended in special cases |
| Payment | Letter of credit (L/C) and T/T |
| Spare parts | Original parts matching each product, supplied within 3–5 days, plus shipping to you |
| Certification | Our products meet CE certification standards. Tell us what your local inspector requires, so we can address it in the quotation |
| Quote requests | Reply within 24 hours |
Buyer’s Checklist: What to Ask Any Cold Room Kit Supplier
Before you order, from us or anyone else, make sure the quote answers these questions:
- Panel core and density. Is it PIR or PUR? What is the density and the fire rating?
- Panel thickness. Is it right for your temperature and your climate?
- Refrigeration sizing. Was the unit sized from a heat load calculation, or picked from a size chart?
- Does it meet current U.S. EPA rules for your type of system?
- Electrical approvals. Do the components meet the requirements of your local electrical inspector (e.g., UL / ETL listed)?
- Is a floor insulation or anti-frost heating solution included for freezers?
- Does it have a heated frame (freezers) and an inside safety release?
- Does it have temperature logging and alarms, which you need for FSMA food safety records?
- What’s NOT included. Freight, duties, installation labor and electrical hookup should be clearly stated.
Cold Storage for the US Food Industry
Food businesses in the United States need a different kind of room for each segment:
- Meat, poultry and seafood processors: blast freezer rooms at –35 to –40 °C, followed by freezer storage at –18 °C or colder.
- Fresh produce and dairy: chilled industrial cold rooms with the right temperature and humidity for each product; dairy is usually kept at 2–4 °C.
- Restaurants, grocery stores and caterers: modular cold rooms that go up quickly and can be enlarged by adding panels.
- Distribution centers and supermarket chains: central cooling systems that serve several rooms at different temperatures.
Temperature records for your food safety plan
Under the FDA Food Safety Modernization Act (FSMA), many food businesses monitor and record cold storage temperatures as part of their food safety plan. Our cold rooms can be fitted with controllers and remote monitoring that log temperature and humidity, keep the history and send an alert when a room drifts from its set point. See our refrigeration monitoring system guide.
Who Buys Our Cold Room Kits
- Food processors: meat, poultry, seafood, dairy and bakery plants
- Distributors and 3PL operators: multi-temperature pallet storage
- Farms and packing houses: fruit and vegetable storage, pre-cooling rooms
- Restaurants, supermarkets and caterers: walk-in coolers and freezers
- Pharmaceutical and healthcare: +2/+8°C controlled storage rooms
Frequently Asked Questions
How much does a cold room kit cost?
It depends on size, temperature, panel thickness and refrigeration capacity. A freezer costs more than a cooler of the same size because it needs thicker panels and a larger unit. Send us your dimensions and temperature for an exact price. For typical ranges, see our walk-in cooler cost guide.
Can I install a cold room kit myself?
Small walk-in kits can be assembled by a general contractor using our drawings. The refrigeration connection and start-up must be done by a licensed refrigeration technician. Electrical work must be done by a licensed electrician.
How long does delivery to the USA take?
Production takes 3–7 weeks on average, depending on the project and order status; sea freight to your nearest port comes on top. We confirm the exact schedule in your quotation.
Do you make custom sizes?
Yes. Every kit is made to order. We can fit rooms around columns, into existing buildings, or build freestanding structures with their own roof.
Can a kit be used outdoors?
Yes. Outdoor rooms get a weather-resistant roof and a protected refrigeration unit.
Do you also supply just the panels or just the refrigeration unit?
Yes. We supply panels, doors and refrigeration units separately as well as complete kits.
Have you delivered projects in the USA?
Yes. Our Houston, Texas project is a turnkey cold storage facility with 5,100 m² of enclosed space.
Which payment terms do you accept?
Letter of credit (L/C) and T/T are accepted.
What warranty do you give?
1 year under standard terms. It can be extended in special cases.
Get Your Cold Room Kit Quote
Tell us five things:
- Inside dimensions (L × W × H)
- Required temperature
- Products you will store
- Delivery location (city/state)
- Site power supply (voltage, phase and frequency)
Our engineers will send a technical proposal with drawings and pricing. For a first estimate of the cooling load, try our heat load calculator.









