Cold Storage Design

There are some points to consider in cold storage design and construction. This is a product type that renders possible cooling installation solutions allowing limitless capacity for all sorts of projects. Coldrooms and product processing areas in desired measures can be set up through the cold room panels.

There is no need for a secondary external frame to protect these cold rooms panels which are laid under a skeleton of prefabricated concrete or of steel construction

Industrial Cold Room Floor
Industrial Cold Room Floor

Building Design and Layout for Cold Storage Design

The floor area needed for refrigerated storage can be calculated by determining the maximum amount of product the facility will be expected to handle in units of volume (m3 or ft3 ) divided by the storage height. Storage height is usually about 2 m, the height of a pallet load. Product height can be increased by adding pallet racks or, if boxes are strong enough, by stacking pallets up to three high. Pallet bins are sometimes stacked to a height of over 3 m. Add to this area space for corridors and space for lift truck movement.

Cold Storage Design and Construction
Cold Storage Design and Construction

Cold Storage Warehouse Layout: Zones, Doors and Product Flow

A good cold storage plan groups rooms by temperature and keeps goods moving in one direction, from receiving to dispatch:

  • Loading dock or anteroom: a chilled buffer between the outside and the cold rooms cuts warm air entry every time a door opens.
  • Chilled rooms (0/+8 °C): fresh produce, dairy and meat. 80 mm panels are usually enough for 0 to +5 °C.
  • Frozen storage (-18/-25 °C): 150 mm panels, floor insulation over a vapour barrier, and in large rooms floor heating so the ground does not freeze.
  • Blast freezing (-35/-40 °C): placed next to frozen storage so product moves straight in after freezing. 200 mm panels.
  • Doors: sliding doors for forklift traffic, with a frame heater below 0 °C. High-speed PVC doors suit busy openings.
  • Room for growth: leave a wall where you can add a room later. Panel buildings extend easily.

Where wall or ceiling panels are longer than 9 m, camlock panels are used. Once your layout is drawn, check the cooling capacity of each room with our free cold room heat load calculator.

Airflow Design for Cold Storage Design

Adequate airflow is needed to distribute refrigerated air throughout the facility to maintain uniform air temperatures. Most cold storage is designed to have an airflow capacity of about 3 m³ per minute per tonne of product (100 cfm per ton). In long-term storage, the product will reach setpoint temperature within a few days to about 1 week after the facility is filled. Airflow can then be reduced to about 20 to 40% of the design capacity and still maintain adequate temperature uniformity. This can be done by intermittent operation of fans or by keeping the fans constantly on but reducing their speed with an electronic speed control system. Slow airspeeds reduce moisture loss from the product. Airflow must be distributed uniformly throughout the cold room to minimize temperature variability. For product in pallet loads, one of three systems is commonly used (Thompson et al. 1998). All three require placement of pallets in lanes separated by 10 to 15 cm (4 to 6 in). In rooms where the air must travel more than 15 m (50 ft), the air is distributed through ceiling ducts or a plenum and returns to evaporators through a long opening in a plenum wall. Another system distributes air into the pallet lanes, and the air returns across the ceiling. Pallet bin storage can use the same systems, or air can be distributed through forklift openings or with a serpentine airflow system, as is used in some forced-air coolers.

Cold Storage Air Flow Design
Cold Storage Air Flow Design

Refrigeration Load for Cold Storage Design

Determining the refrigeration capacity needed for a facility is based on estimating heat input to the cold storage from the following: uncooled product; product respiration; heat conduction through walls, floors, and roof; air infiltration through doors; lights; motors; equipment; and personnel. However, these estimates cannot be done exactly. Over the life of a facility, it may be used for different products, the amount of product may change, and equipment performance deteriorates over time. Coldroom designers make estimates based on methods presented in Stoecker (1998) or ASHRAE (1999) and then add perhaps 20 to 30% extra capacity as a cushion. As a rule of thumb, refrigerated produce storage requires 10 to 14 kW of refrigeration capacity per 1,000 m3 of storage volume and refrigerated shipping docks require 14 to 25 kW per 1,000 m3 (Stoecker 1998).

Calculating Heat Load
Calculating Heat Load

Refrigeration Equipment selection for Cold Storage

Most cold storage uses vapor recompression, also called mechanical refrigeration. A few facilities use absorption refrigeration, though this is only cost-effective if there is an inexpensive source of low-temperature heat available. Detailed discussions of equipment selection and design are given in Stoecker (1998) and ASHRAE (1999).

The key design constraint for produce storage is uniformly maintaining the desired temperature and relative humidity (RH). Uniform temperature is maintained by adequate refrigeration capacity, uniform air distribution, minimal temperature difference between the evaporator coil and the air temperature, and a precise temperature control system. High RH is needed to reduce product moisture loss. Most fresh produce requires 85 to 95% RH, while dried commodities, such as onion and ginger, need a low RH. High RH is obtained by minimizing temperature variation in the room and by operating the evaporator coil at a temperature close to the setpoint temperature of the room.

This is done by installing a coil with a high surface area and by using a control system that maintains the refrigerant at its highest possible temperature. Humidifiers may be needed to add moisture to paper or wood packaging materials; otherwise, packaging will absorb water from the product. Alternatively, the product can be packed in plastic packages that do not absorb water or in plastic bags that slow moisture loss. Plastic materials with minimum amounts of venting retard moisture loss from the produce (Crisosto et al. 1994) and may allow the cold storage to be held at lower humidity. Products with low transpiration coefficients lose water slowly (Sastry and Baird 1978) and may not need special provisions for high RH storage, especially if they are not stored for a long time.

Source

Cold Room Equipments
Cold Room Equipments

Cold Storage Planning Checklist

Before a cold storage plan can be drawn and priced, collect these details:

  • Product and daily intake: what you will store and how many kilograms enter the room each day.
  • Room temperature: chilled (0/+8 °C), frozen (-18/-25 °C) or blast freezing (-35/-40 °C).
  • Inside dimensions: length × width × height, or the quantity to store in tons or pallets.
  • Doors and traffic: how goods move in and out, by hand, pallet truck or forklift.
  • Site conditions: the power supply (for example 380 V / 50 Hz or 460 V / 60 Hz) and the highest outdoor temperature in summer.
  • Delivery: the city or port where the panels and equipment will be shipped.

From Cold Storage Plan to a Working Facility

When you send us your checklist, this is what happens next:

  • Within 24 hours: our engineers reply with questions or a quotation that lists panels, doors, refrigeration, floor insulation and installation item by item.
  • Delivery terms: EXW from our factory or CIF to your port. Payment by L/C or T/T.
  • Production: 3–7 weeks on average, depending on the project.
  • Shipping: panels, doors and units are packed at our factory and loaded into containers. A 600 m² frozen store fits in about 4–5 containers.
  • Installation: our own team installs the cold store, or we send a supervisor to lead your local installers.

We have more than 15 years in the sector and export to more than 40 countries, including Kenya, Tanzania, Ghana and The Gambia. Share your plan through our contact page and get a design proposal for your cold storage.

You can estimate the cooling capacity with our free cold room heat load calculator. Send these details through the quote form and our engineers will prepare a proposal for the panels, doors and refrigeration equipment. We reply within 24 hours.

Planning a cold room? Send us your dimensions and product type for a quote. We reply within 24 hours.

Latest Posts

Frozen storage room in Banjul, The Gambia, with evaporators and LED lighting

Cold Rooms in West Africa: Ghana, Senegal and The Gambia

Frigo System supplies cold rooms to West Africa from Turkey….

Freezer store under construction inside a hall in Arusha, Tanzania

Cold Rooms in Tanzania: Supply, Installation and Projects

Frigo System supplies cold rooms to Tanzania from Turkey. We…

Fresh fruit cold room in Nairobi, Kenya, with evaporator and LED lighting

Cold Rooms in Kenya: Supply, Installation and Projects

Frigo System supplies cold rooms to Kenya from Turkey: sandwich…

Cold room by Frigo System

Cold Room Prices: What Decides the Cost? A 600 m² Project Example

What decides the price of a cold room: size, temperature,…
Precooling Room

High Ambient Condensing Units for Cold Rooms

High ambient condensing units for cold rooms are the difference…
FM Approved PIR Sandwich Panels

Cold Room Kit – Factory Direct to the USA

Need a walk-in cooler, freezer, or multi-room cold storage facility…
3D view of a pharmaceutical cold room

Pharmaceutical Cold Storage: US GMP Room Guide

In pharmaceutical logistics, a single hour outside the labeled range…
FM Approved PIR Sandwich Panels

FM Approved PIR Sandwich Panels

If you are planning a cold storage, food processing, pharmaceutical,…
Electronic expansion valve driver

Cold Room Controllers: What Every Buyer Should Know

When investing in a cold room or industrial cold storage…
Cold Storage Solutions Africa

Cold Storage Solutions in Africa: Tanzania, Ghana, Kenya

Cold storage solutions Africa are becoming one of the most…